华为ICC710-HD1-C1室外柜,通信电源,5G基站电源柜,一体化室外电源柜
ICC710-HD1-C1外观
内部结构图3-8:ICC710-HD1-C1的内部结构(前)
(1) RTN+铜排
(2) 热交换
(3) 风扇箱
(4) 接线板
(5) DCDU-400AN2型
(6) -48V铜排
(7) 电池安装空间
图3-9 ICC710-HD1-C1的内部结构(背面)
(1) 接地棒
技术指标表3-7 ICC710-HD1-C1技术指标
项目
解释
室外机柜
温度控制:
设备隔间:热交换,散热150W/K(当温度在40-45℃和太阳辐射之间时,热交换散热降低到110W/K)
蓄电池室:直接通风
外形尺寸(高×宽×深:1925mm×900mm×1120mm
底座尺寸(高×宽×深:150mm×900mm×950mm
重量:300kg
安装方式:落地安装
维护方式:前端维护
接线方式:自下而上
工作温度
-10℃至+40℃(使用TCB-C电池时,温度范围:-10℃至+45℃)
解释:
当温度低于-5℃时,可能会出现电池温度过低警报,影响电池的备份性能。
运输温度
–40℃~+70℃
储存温度
–40℃~+70℃
工作湿度
5%相对湿度至95%相对湿度(无冷凝)
海拔高度要求
0m~4000m(在2000m~4000m的高温降额环境下,每增加200m,运行温度下降1℃)
噪声水平
符合GR487的要求,噪声压力≤65dBA@1.5m(环境温度为45℃时)
防护等级和工作环境
IP55,C级环境
其他要求
无导电粉尘和腐蚀性气体,无爆炸危险
灰尘水平、腐蚀性物质、有害生物、霉菌和其他指标应符合ETSI EN 300 019-1-4(V2.2.1)4.1级的要求





Appearance Figure 3-7 Appearance of ICC710-HD1-C1
Internal structure diagram 3-8: Internal structure of ICC710-HD1-C1 (front)
(1) RTN+copper bar
(2) Heat exchange
(3) Fan box
(4) Wiring panel
(5)DCDU-400AN2
(6) -48V copper bar
(7) Battery installation space
Figure 3-9 Internal Structure of ICC710-HD1-C1 (Back)
(1) Grounding bar
Technical Indicators Table 3-7 Technical Indicators of ICC710-HD1-C1
project
explain
Outdoor cabinet
Temperature control:
Equipment compartment: heat exchange, heat dissipation 150W/K (when the temperature is between 40-45 ℃ and solar radiation, the heat exchange heat dissipation is reduced to 110W/K)
Battery compartment: direct ventilation
Overall dimensions (height × wide × Depth: 1925mm × 900mm × 1120mm
Base size (height × wide × Depth: 150mm × 900mm × 950mm
Weight: 300kg
Installation method: floor mounted
Maintenance method: front maintenance
Wiring method: bottom in and bottom out
working temperature
-10 ℃ to+40 ℃ (when using TCB-C batteries, temperature range: -10 ℃ to+45 ℃)
explain:
When the temperature is below -5 ℃, a low battery temperature alarm may occur, affecting the battery's backup performance.
Transportation temperature
–40℃~+70℃
Storage temperature
–40℃~+70℃
Working humidity
5% RH to 95% RH (without condensation)
Altitude requirements
0m~4000m (under high temperature derating in an environment of 2000m~4000m, the operating temperature decreases by 1 ℃ for every 200m increase)
Noise level
Meet the requirements of GR487, with noise pressure ≤ 65dBA@1.5m (At an ambient temperature of 45 ℃)
Protection level and working environment
IP55, Class C environment
Other requirements
No conductive dust and corrosive gases, no explosion hazard
Dust level, corrosive substances, harmful organisms, mold and other indicators should comply with the requirements of ETSI EN 300 019-1-4 (V2.2.1) Class 4.1